NYKB Series

              Miniature Circuit Breaker

              (1A-125A)

              Intelligent Convenient Safe Comprehensive

              PRODUCT OVERVIEW

              Miniature circuit breaker is a kind of circuit protection equipment usually used in low-voltage circuits. Its main function is to quickly cut off the circuit when detecting abnormalities of the current (such as overload or short-circuit), so as to protect the electrical equipment and personal safety. It can prevent the damage caused by the circuit overload, short-circuit and other faults, while ensuring the normal operation of the circuit.

              NYKB series miniature circuit breakers can quickly cut off the power supply when the circuit is abnormal to protect the safety of equipment and personnel. It has stable operating performance and long service life, which is suitable for being installed in places with limited space places with limited space, such as electrical control cabinets, household appliances, etc. A variety of rated currents and rated voltages are optional to meet the needs of different circuits.

              PRODUCT CHARACTERITICS

              NYKB Series Miniature Circuit Breaker

              Efficient current limiting and arc extinguishing capability, safer and clearer isolation function, reliable and stable overcurrent protection performance.

              Built-in tripping indication

              More assured operation

              Leakage protection function

              Safer electricity use

              Guide rail mounted

              More convenient installation

              PRODUCT DIVERSITY

              A wide range of product specifications provide multiple choices

              NYKB1h Series

              NYKB2 Series

              NYKB3 Series

              NYKB5 Series

              Technical Parameters

              NYKB1H Series Miniature Circuit Breaker

              Model Rated currentIn (A) Tripping curve Impulse withstand voltage Uimp(kV) Breaking capacity (kA) Rated voltage(V) Number of poles Modulus (Multiple of 9mm)
              NYKB1H 1 C、D 4 6 AC 230/400 1P、2P、 3P、4P 2、4、6、8
              NYKB1H 2 4 6
              NYKB1H 3 4 6
              NYKB1H 4 4 6
              NYKB1H 6 4 6
              NYKB1H 10 4 6
              NYKB1H 16 4 6
              NYKB1H 20 4 6
              NYKB1H 25 4 6
              NYKB1H 32 4 6
              NYKB1H 40 4 6
              NYKB1H 50 4 6
              NYKB1H 63 4 6

              NYKB1HL Series Miniature Circuit Breaker

              Model Rated currentIn (A) Tripping curve Impulse withstand voltage Uimp(kV) Breaking capacity (kA) Rated voltage(V) Number of poles Modulus (Multiple of 9mm) Rated residual action current (mA)
              NYKB1HL 6 C、D 4 6 AC 230/400 1P+N、2P、3 P、3P+N、4P 5、6、7、8、 10、11、11.5、 13、15 30、50、 100、300
              NYKB1HL 10 4 6
              NYKB1HL 16 4 6
              NYKB1HL 20 4 6
              NYKB1HL 25 4 6
              NYKB1HL 32 4 6
              NYKB1HL 40 4 6
              NYKB1HL 50 4 6
              NYKB1HL 63 4 6

              NYKB2 Series Miniature Circuit Breaker

              Model Rated currentIn (A) Tripping curve Breaking capacity (kA) Rated voltage(V) Number of poles Modulus (Multiple of 9mm)
              NYKB2 6 C、D 4.5 AC 230 1P+N 2
              NYKB2 10 4.5
              NYKB2 16 4.5
              NYKB2 20 4.5
              NYKB2 25 4.5
              NYKB2 32 4.5

              NYKB2L Series Miniature Circuit Breaker

              Model Rated currentIn (A) Tripping curve Breaking capacity (kA) Rated voltage(V) Number of poles Modulus (Multiple of 9mm) Rated residual action current (mA)
              NYKB2L 6 C、D 4.5 AC 230 1P+N 4 30、50、 100、300
              NYKB2L 10 4.5
              NYKB2L 16 4.5
              NYKB2L 20 4.5
              NYKB2L 25 4.5
              NYKB2L 32 4.5

              NYKB3 Series Miniature Circuit Breaker

              Model Rated currentIn (A) Instantaneous tripping current Impulse withstand voltage Uimp(kV) Breaking capacity (kA) Rated voltage(V) Number of poles Modulus (Multiple of 9mm)
              NYKB3 63 10In、12In 6 10 AC 230/400 1P、2P、 3P、4P 3、6、9、12
              NYKB3 80 6 10
              NYKB3 100 6 10
              NYKB3 125 6 10

              NYKB5 Series Miniature Circuit Breaker

              Model Rated currentIn (A) Tripping curve Mechanical life(Times) Breaking capacity (kA) Rated voltage(V) Number of poles Modulus (Multiple of 9mm)
              NYKB5 6 C、D 4000 10 AC 230/400 1P、2P、 3P、4P 2、4、6、8
              NYKB5 10 4000 10
              NYKB5 16 4000 10
              NYKB5 20 4000 10
              NYKB5 25 4000 10
              NYKB5 32 4000 10
              NYKB5 40 4000 10
              NYKB5 50 4000 10
              NYKB5 63 4000 10

              NYKB5L Series Miniature Circuit Breaker

              Model Rated currentIn (A) Tripping curve Mechanical life(Times) Breaking capacity (kA) Rated voltage(V) Number of poles Modulus (Multiple of 9mm) Rated residual action current(mA)
              NYKB5L 6 C、D 4000 10 AC 230/400 1P+N、2P、3 P、3P+N、4P 2、4、6、8 30、50、 100、300
              NYKB5L 10 4000 10
              NYKB5L 16 4000 10
              NYKB5L 20 4000 10
              NYKB5L 25 4000 10
              NYKB5L 32 4000 10
              NYKB5L 40 4000 10
              NYKB5L 50 4000 10
              NYKB5L 63 4000 10
              Selection table

              NYKB1H Series Miniature Circuit Breaker

              NYKB1H 3P C 16A Additional functions
              Product code Pole No. Tripping characteristics Rated current Additional functions
              NYKB1H:
              Miniature Circuit Breaker
              1P:1 pole
              2P:2 pole
              3P:3 pole
              4P:4 pole
              C type
              D type
              1A
              2A
              3A
              4A
              6A
              10A
              16A
              20A
              25A
              32A
              40A
              50A
              63A
              SD:Alarm
              OF:Auxiliary
              OF+OF:Double auxiliary
              OF+SD:Auxiliary+Alarm
              MX+OF:Shunt release+Auxiliary
              MV:Overvoltage tripper
              MN:Under-voltage tripper
              MV+MN:Over-voltage and under-voltage trippers

              NYKB1HL Series Miniature Circuit Breaker

              NYKB1HL 3P C 16A 30mA Additional functions
              Product code Pole No. Tripping characteristics Rated current Residual current Additional functions
              NYKB1HL:
              Leakage protection circuit breaker
              1P+N:1 pole+N
              2P:2 pole
              3P+N:3 pole+N
              4P:4 pole
              C type
              D type
              6A
              10A
              16A
              20A
              25A
              32A
              40A
              50A
              63A
              30mA
              50mA
              100mA
              300mA
              SD:Alarm
              OF:Auxiliary
              OF+OF:Double auxiliary
              OF+SD:Auxiliary+Alarm
              MX+OF:Shunt release+Auxiliary
              MV:Overvoltage tripper
              MN:Under-voltage tripper
              MV+MN:Over-voltage and under-voltage trippers

              NYKB2 Series Miniature Circuit Breaker

              NYKB2 1P+N C 16A
              Product code Pole No. Tripping characteristics Rated current
              NYKB2:
              Miniature Circuit Breaker
              1P+N:1 pole+N C type
              D type
              6A
              10A
              16A
              20A
              25A
              32A

              NYKB2L Series Miniature Circuit Breaker

              NYKB2L 1P+N C 16A 30mA
              Product code Pole No. Tripping characteristics Rated current Residual current
              NYKB2L:
              Leakage Protection Circuit Breaker
              1P+N:1 pole+N C type
              D type
              6A
              10A
              16A
              20A
              25A
              32A
              30mA
              50mA
              100mA
              300mA

              NYKB3 Series Miniature Circuit Breaker

              NYKB3 3P 100A Additional functions
              Product code Pole No. Rated current Additional functions
              NYKB3:
              Miniature Circuit Breaker
              1P:1 pole
              2P:2 pole
              3P:3 pole
              4P:4 pole
              63A
              80A
              100A
              125A
              SD:Alarm
              OF:Auxiliary
              OF+OF:Double auxiliary
              OF+SD:Auxiliary+Alarm
              MX+OF:Shunt release+Auxiliary
              MV:Overvoltage tripper
              MN:Under-voltage tripper
              MV+MN:Over-voltage and under-voltage trippers

              NYKB5 Series Miniature Circuit Breaker

              NYKB5 3P C 16A Additional functions
              Product code Pole No. Tripping characteristics Rated current Additional functions
              NYKB5:
              Miniature Circuit Breaker
              1P:1 pole
              2P:2 pole
              3P:3 pole
              4P:4 pole
              C type
              D type
              6A
              10A
              16A
              20A
              25A
              32A
              40A
              50A
              63A
              SD:Alarm
              OF:Auxiliary
              OF+OF:Double auxiliary
              OF+SD:Auxiliary+Alarm
              MX+OF:Shunt release+Auxiliary
              MV:Overvoltage tripper
              MN:Under-voltage tripper
              MV+MN:Over-voltage and under-voltage trippers

              NYKB5L Series Miniature Circuit Breaker

              NYKB5L 3P C 16A 30mA Additional functions
              Product code Pole No. Tripping characteristics Rated current Residual current Additional functions
              NYKB5L:
              Leakage Protection Circuit Creaker
              1P+N:1 pole+N
              2P:2 pole
              3P+N:3 pole+N
              4P:4 pole
              C type
              D type
              6A
              10A
              16A
              20A
              25A
              32A
              40A
              50A
              63A
              30mA
              50mA
              100mA
              300mA
              SD:Alarm
              OF:Auxiliary
              OF+OF:Double auxiliary
              OF+SD:Auxiliary+Alarm
              MX+OF:Shunt release+Auxiliary
              MV:Overvoltage tripper
              MN:Under-voltage tripper
              MV+MN:Over-voltage and under-voltage trippers
              Technical Parameters


              • Model:NYKB1H

                Rated currentIn (A):1、2、3、4、10、16、20、25、32、40、50、63

                Tripping curve:C、D

                Impulse withstand voltage Uimp(kV):4

                Breaking capacity (kA):6

                Rated voltage(V):AC 230/400

                Number of poles :1P、2P、 3P、4P

                Modulus (Multiple of 9mm) :2、4、6、8

              • Model:NYKB1HL

                Rated currentIn (A):6、10、16、20、25、32、40、50、63

                Tripping curve:C、D

                Impulse withstand voltage Uimp(kV):4

                Breaking capacity (kA):6

                Rated voltage(V):AC 230/400

                Number of poles :1P+N、2P、3 P、3P+N、4P

                Modulus (Multiple of 9mm) :5、6、7、8、 10、11、11.5、 13、15

                Rated residual action current (mA) :30、50、 100、300

              • Model:NYKB2

                Rated currentIn (A):6、10、16、20、25、32

                Tripping curve:C、D

                Breaking capacity (kA):4.5

                Rated voltage(V):AC 230

                Number of poles :1P+N

                Modulus (Multiple of 9mm) :2

              • Model:NYKB2L

                Rated currentIn (A):6、10、16、20、25、32

                Tripping curve:C、D

                Breaking capacity (kA):4.5

                Rated voltage(V):AC 230

                Number of poles :1P+N

                Modulus (Multiple of 9mm) :4

                Rated residual action current (mA) :30、50、 100、300

              • Model:NYKB3

                Rated currentIn (A):63、80、100、125

                Instantaneous tripping current:10In、12In

                Impulse withstand voltage Uimp(kV):6

                Breaking capacity (kA):10

                Rated voltage(V):AC 230/400

                Number of poles :1P、2P、 3P、4P

                Modulus (Multiple of 9mm) :3、6、9、12

              • Model:NYKB5

                Rated currentIn (A):6、10、16、20、25、32、40、50、63

                Tripping curve:C、D

                Mechanical life(Times):4000

                Breaking capacity (kA):10

                Rated voltage(V):AC 230/400

                Number of poles :1P、2P、 3P、4P

                Modulus (Multiple of 9mm) :2、4、6、8

                Rated residual action current (mA) :30、50、 100、300

              • Model:NYKB5L

                Rated currentIn (A):6、10、16、20、25、32、40、50、63

                Tripping curve:C、D

                Mechanical life(Times):4000

                Breaking capacity (kA):10

                Rated voltage(V):AC 230/400

                Number of poles :1P+N、2P、 3P+N、4P

                Modulus (Multiple of 9mm) :2、4、6、8

                Rated residual action current (mA):30、50、 100、300

              Selection table


              • Product code :NYKB1H:Miniature Circuit Breaker

                Pole No.:1P:1 pole、2P:2 pole、3P:3 pole、4P:4 pole

                Tripping characteristics:C type、D type

                Rated current:1A、2A、3A、4A、6A、10A、16A、20A、25A、32A、40A、50A、63A

                Additional functions:SD:Alarm、OF:Auxiliary、OF+OF:Double auxiliary、OF+SD:Auxiliary+Alarm、MX+OF:Shunt release+Auxiliary、MV:Overvoltage tripper、MN:Under-voltage tripper、MV+MN:Over-voltage and under-voltage trippers

              • Product code:NYKB1HL:Leakage protection circuit breaker

                Pole No.:1P+N:1 pole+N、2P:2 pole、3P+N:3 pole+N、4P:4 pole

                Tripping characteristics:C type、D type

                Rated current:6A、10A、16A、20A、25A、32A、40A、50A、63A

                Residual current :30mA、50mA、100mA、300mA

                Additional functions:SD:Alarm、OF:Auxiliary、OF+OF:Double auxiliary、OF+SD:Auxiliary+Alarm、MX+OF:Shunt release+Auxiliary、MV:Overvoltage tripper、MN:Under-voltage tripper、MV+MN:Over-voltage and under-voltage trippers

              • Product code :NYKB2:Miniature Circuit Breaker

                Pole No.:1P+N:1 pole+N

                Tripping characteristics:C type、D type

                Rated current:6A、10A、16A、20A、25A、32A

              • Product code :NYKB2L: Leakage Protection Circuit Breaker

                Pole No.:1P+N:1 pole+N

                Tripping characteristics:C type、D type

                Rated current:6A、10A、16A、20A、25A、32A

              • Product code :NYKB3:Miniature Circuit Breaker

                Pole No.:1P:1 pole、2P:2 pole、3P:3 pole、4P:4 pole

                Rated current:63A、80A、100A、125A

                Additional functions:SD:Alarm、OF:Auxiliary、OF+OF:Double auxiliary、OF+SD:Auxiliary+Alarm、MX+OF:Shunt release+Auxiliary、MV:Overvoltage tripper、MN:Under-voltage tripper、MV+MN:Over-voltage and under-voltage trippers

              • Product code :NYKB5:Miniature Circuit Breaker

                Pole No.:1P:1 pole、2P:2 pole、3P:3 pole、4P:4 pole

                Tripping characteristics:C type、D type

                Rated current:6A、10A、16A、20A、25A、32A、40A、50A、63A

                Additional functions:SD:Alarm、OF:Auxiliary、OF+OF:Double auxiliary、OF+SD:Auxiliary+Alarm、MX+OF:Shunt release+Auxiliary、MV:Overvoltage tripper、MN:Under-voltage tripper、MV+MN:Over-voltage and under-voltage trippers

              • Product code :NYKB5L:NYKB5L: Leakage Protection Circuit Creaker

                Pole No.:1P+N:1 pole+N、2P:2 pole、3P+N:3 pole+N、4P:4 pole

                Tripping characteristics:C type、D type

                Rated current:6A、10A、16A、20A、25A、32A、40A、50A、63A

                Residual current :30mA、50mA、100mA、300mA

                Additional functions:SD:Alarm、OF:Auxiliary、OF+OF:Double auxiliary、OF+SD:Auxiliary+Alarm、MX+OF:Shunt release+Auxiliary、MV:Overvoltage tripper、MN:Under-voltage tripper、MV+MN:Over-voltage and under-voltage trippers