Surge Backup Protection Circuit Breaker

              NYKU1H-I Series Class T1 (15-25KA)

              NYKU1H Series Class T2 (10-120KA)

              Concise Efficient Safe Comprehensive

              PRODUCT OVERVIEW

              NYKU1H series surge backup protection circuit breakers are mainly used to protect electrical appliances or power equipment from surges. It features fast response and low impedance, and can introduce high voltage and overcurrent to the ground in a very short time to protect the backup equipment and lines, which is especially significant for environments requiring a high degree of reliability and data security.

              PRODUCT CHARACTERISTICS

              Effectiveness

              Compared with conventional MCB protection solutions, the residual voltage at both ends is lower when a surge occurs, thus the equipment can be better protected.

              Accuracy

              When there is lightning current in the SPD, the device will not be mistakenly tripped, ensuring that the lightning protection of electrical equipment is always effective.

              High safety coefficient

              Selectively disconnects the passing industrial frequency current and lightning current, which can effectively avoid SPD from fused short-circuits, and avoid causing serious fire accidents.

              Compliance with the specification requirements

              Complies with national and international electrical safety standards, ensuring legality and reliability and boosting user confidence.

              Technical parameters

              NYKU1H-I series surge backup protection circuit breaker technical parameters

              Model specification NYKU1H-I 15 NYKU1H-I 25
              Rated operating voltage Ue 230V/400V
              Rated insulation voltage Ui 400V
              Number of poles 1P、2P、3P、4P
              Category of adaptation to SPD Category I (T1)
              Waveform 10/350us
              Impulse current limp 15kA 25kA
              Nominal discharge current In 15KA/25kA 15KA/25kA
              Current tripping value Io 3A±1A
              Breaking time of industrial frequency short-circuit current Tos ≤40ms
              Breaking time of industrial frequency load current Tos ≤50ms

              NYKU1H series surge backup protection circuit breaker technical parameters

              Model specification NYKU1H-10 NYKU1H-20 NYKU1H-40kA NYKU1H-60kA
              Rated operating voltage Ue 230V/400V
              Rated insulation voltage Ui 500V
              Number of poles 1P、2P、3P、4P
              Category of adaptation to SPD Category II (T2)
              Waveform 8/20us
              Maximum discharge current Imax 10kA 20kA 40kA 60kA
              Nominal discharge current In 5kA 10kA 20kA 30kA
              Current tripping value Io 3A±1A
              Breaking time of industrial frequency short-circuit current Tos ≤40ms
              Breaking time of industrial frequency load current Tos ≤50ms

              NYKU1H-I Series Surge Backup Protection Circuit Breaker

              Model specification NYKU1H-80kA NYKU1H-100kA NYKU1H-120kA
              Rated operating voltage Ue 230V/400V
              Rated insulation voltage Ui 500V
              Number of poles 1P、2P、3P、4P
              Category of adaptation to SPD Class II(T2)
              Waveform 8/20us
              Maximum discharge current Imax 80kA 100kA 120kA
              Nominal discharge current In 40kA 50kA 60kA
              Current tripping value Io 3A±1A
              Breaking time of industrial frequency short-circuit current Tos ≤40ms
              Breaking time of industrial frequency load current Tos ≤50ms
              Selection table

              NYKU1H-I Series Surge Backup Protection Circuit Breaker

              NYKU1H I 15kA 4P
              Product code Use category Maximum impulse current Number of poles
              NYKU1H:
              Surge Backup Protection Circuit Breaker
              I:Class T1 15kA
              25kA
              1P:1 pole
              2P:2 pole
              3P:3 pole
              4P:4 pole

              NYKU1H SeriesSurge Backup Protection Circuit Breaker

              NYKU1H 10kA 4P
              Product code Maximum discharge current Number of poles
              NYKU1H:
              Surge Backup Protection Circuit Breaker
              10kA
              20kA
              40kA
              60kA
              80kA
              100kA
              120kA
              1P:1 pole
              2P:2 pole
              3P:3 pole
              4P:4 pole

              Technical Parameters


              Surge Backup Protection Circuit Breaker

              • Model specification :NYKU1H-I 15kA/NYKU1H-I 25kA

                Rated operating voltage Ue:230V/400V

                Rated insulation voltage Ui:400V

                Number of poles:1P、2P、3P、4P

                Category of adaptation to SPD:Class I (T1)

                Waveform:10/350us

                Impulse current limp:15kA/25kA

                Nominal discharge current In:15kA、25kA/15kA、25kA

                Current tripping value Io:3A±1A

                Breaking time of industrial frequency short-circuit current Tos:≤40ms

                Breaking time of industrial frequency load current Tos:≤50ms

              • Model specification :NYKU1H- 10kA/NYKU1H-20kA/NYKU1H-40kA/NYKU1H-60kA

                Rated operating voltage Ue:230V/400V

                Rated insulation voltage Ui:500V

                Number of poles:1P、2P、3P、4P

                Category of adaptation to SPD:IClass I (T2)

                Waveform:8/20us

                Maximum discharge current Imax:10kA/20kA/40kA/60kA

                Nominal discharge current In:5kA/10kA/20kA/30kA

                Current tripping value Io:3A±1A

                Breaking time of industrial frequency short-circuit current Tos:≤40ms

                Breaking time of industrial frequency load current Tos:≤50ms

              • Model specification :NYKU1H- 80kA/NYKU1H-100kA/NYKU1H-120kA

                Rated operating voltage Ue:230V/400V

                Rated insulation voltage Ui:500V

                Number of poles: 1P、2P、3P、4P

                Category of adaptation to SPD:IClass I (T2)

                Waveform:8/20us

                Maximum discharge current Imax:80kA/100kA/120kA

                Nominal discharge current In:40kA/50kA/60kA

                Current tripping value Io:3A±1A

                Breaking time of industrial frequency short-circuit current Tos:≤40ms

                Breaking time of industrial frequency load current Tos:≤50ms

              Selection table


              Surge Backup Protection Circuit Breaker

              • Product code :NYKU1H:Surge Backup Protection Circuit Breaker

                Use category:I:Class T1

                Maximum impulse current:15kA、25kA

                Number of poles:1P:1 pole、2P:2 pole、3P:3 pole、4P:4 pole

              • Product code :NYKU1H:Surge Backup Protection Circuit Breaker

                Maximum discharge current :10kA、20kA、40kA、60kA、80kA、100kA、120kA

                Number of poles:1P:1 pole、2P:2 pole、3P:3 pole、4P:4 pole