KLD-AP Series

              Arc Protection System

              Designed in accordance with the standards of electromagnetic compatibility and relay protection, it has strong anti-interference ability, continuous and comprehensive self-test function to have judgements through overcurrent and arc dual modes, which is easy for installation and use.

              PRODUCT OVERVIEW

              The arc light protection system protects the operators from injury and reduces the property damage when an arc fault occurs in a switchgear cabinet. When it occurs, the arc light explodes at 300m/s, destroying anything in its path. As long as there is an uninterrupted power in the system, the arc light will always exist in the system. To minimize the hazards of arclight, we need a safe, fast and effective arc light protection system.

              KLD-AP series arc protection system can quickly detect arc faults and trip the circuit breakers. In order to ensure the reliability of the system, the arc protection system needs to meet two criterions to take actions: arc light and overcurrent. The system will send a trip command signal when it detects both arc light and current increments; and the system will send an alarm signal, not a trip command signal when it only detects arc light or current increments.

              Double criterion ensures the reliability of the action taken by the whole set of equippment, and the output trip signal is fast (<1ms)that can cross all other protection and delay, which is of great significance. The response time is calculated in milliseconds.

              DOUBLE CRITERION

              Breaking through the principle of conventional protection, it adopts two non-associated parameters (electric quantity and non electric quantity) of arc light and current as the criterion, which has a lower malfunction probability and higher reliability than other protection.

              MODULAR COMBINATION

              KLD-AP series arc light protection system can improve the performance for the whole system by adding current unit, arc light unit and other modular components. It can meet different protection needs of users and accommodate 256 monitoring points.

              ●    Main control system

              The core component of the arc light protection system is used to manage and control the whole arc light protection system. It can protect the switchgear when only arc light occurs, transfer the alarm information to the upper computer, and perform the monitoring and management functions.

              ●    Current unit

              It is used to detect the overcurrent signal of the power inlet cabinet to ensure the operability of the tripping logic of the arc-light protection system under different operating conditions.

              ●    Arc light unit

              The main control system can expand the detection points by connecting the arc light unit externally.

              ●    Arc light detection unit

              A passive arc-light detection unit dedicated to busbar protection is a light-sensing component for arc detection.

              SYSTEM WIRING DIAGRAM

              The main control system needs to be paired with the current unit and the arc light unit to protect the busbar from arc light.

              The main control system and the arc light unit detect the arc light situation in different areas respectively. At the same time, the current unit collects the current signal, the arc light unit detects the arc light signal and transmits the signal to the main control system through optical fiber, so as to protect the busbar from arc light.

              Technical Parameters

              Main control system KLD-AP-MCU-H
              Operating voltage DC 12V
              Respond time <1ms
              Input 16 optical signal inlets (arc light detection unit)
              4 optical comprehensive signal inlets
              4 data transmission ports
              Outputt 4 fast trip outlets 5A, 600VP
              6 trip outlets,Relay output5A,250VAC
              1 optical signal outlet
              RS485 Communication interface
              Current unit KLD-AP-CTE-H
              Input 5A、2A、1A(configurable)
              1 optical comprehensive signal inlet
              1 data transmission port
              Outputt 1 optical signal outlet
              1 data transmission port
              Overcurrent setting 50%In~500%In
              Arc light unit KLD-AP-ACU-H
              Input 10 optical signal inlets (Arc light detection unit)
              1 optical comprehensive signal inlet
              1 data transmission port
              Outputt 1 optical signal outlet
              1 data transmission port
              Illuminance setting 10kLux-50kLux
              Arc light detection unit KLD-AP-AS-H
              Maximum wiring distance ≤100m

              S SeriesAutomatic fire extinguishing equippment KLD-FAE-ED1S
              Protection space ≤3m3(others can be customized)
              Release time ≤30s
              Spray surface temperature ≤200℃
              Thermal clearance 100mm at the nozzle≤75℃
              Product insulation performance ≥20MΩ
              Service life 10 years
              Ambient temperature -40℃~+125℃
              EnvironmentHumidity Maximum 95%RH (no condensing)
              Altitude <1500 meters (higher altitude can be customized)
              Protection degree IP20(other requirements can be customized)
              Starting mode Thermal sensitive wire

              Technical Parameters


              • Operating voltage:DC 12V

                Respond time:<1ms

                Input:16 optical signal inlets (arc light detection unit);4 optical comprehensive signal inlets;4 data transmission ports

                Output:4 fast trip outlets 5A, 600VP;6 trip outlets,Relay output5A,250VAC;1 optical signal outlet;RS485 Communication interface

              • Input:5A、2A、1A(configurable);1 optical comprehensive signal inlet;1 data transmission port

                Output:1 optical signal outlet;1 data transmission port

                Overcurrent setting:50%In~500%In

              • Input:10 optical signal inlets (Arc light detection unit);1 optical comprehensive signal inlet;1 data transmission port

                Output:1 optical signal outlet;1 data transmission port

                Illuminance setting:10kLux-50kLux

              • Maximum wiring distance:≤100m

              • Protection space:≤3m3(others can be customized)

                Release time:≤30s

                Spray surface temperature:≤200℃

                Thermal clearance:100mm at the nozzle≤75℃

                Product insulation performance:≥20MΩ

                Service life:10 years

                Ambient temperature:-40℃~+125℃

                EnvironmentHumidity:Maximum 95%RH (no condensing)

                Altitude:<1500 meters (higher altitude can be customized)

                Protection degree:IP20(other requirements can be customized)

                Starting mode:Thermal sensitive wire